Tanda BioTech Contact us

Find what you need from your unit operations or your product types.

Unit operations we support.

Every operation below runs under automated, weight-based control, so a run is reproducible between operators and between days.

TFF

Tangential Flow Filtration

Cross-flow concentration and clarification that keeps flux up on fouling-prone material — the workhorse for cells, vesicles, particles and proteins.

0.5 mL – 2 L · TxFlow™ Go · Concentration mode
See the platform →
NFF

Direct Flow Filtration

Normal-flow (dead-end) filtration for sterile, depth, clarification and virus-removal steps, on the same system as TFF.

1 mL – 2 L · TxFlow™ Go · Auto stop on pressure, time or weight
See the platform →
DF

Diafiltration & Buffer Exchange

Continuous-volume diafiltration for buffer exchange, desalting and formulation — faster and cleaner than dialysis.

0.5 mL – 2 L · ReadyPath™ · Diafiltration mode
See the platform →
CW

Constant Weight Maintenance

Holds retentate weight constant while permeate is removed, for extended washes and fed-batch style additions without an operator.

0.5 mL – 2 L · TxFlow™ Go · Constant Weight mode
See the platform →
CL

Clarification & Depth Filtration

Removal of cells, debris and aggregates ahead of a capture step, with reproducible weight-based endpoints.

10 mL – 2 L · Direct flow · Auto termination
See the platform →
VR

Virus Removal & Sterile Filtration

Sterilising-grade and virus-removal filtration for buffers, media and product streams under the same automated control.

50 mL – 2 L · Direct flow · Auto termination
See the platform →
PF

Perfusion & Cell Retention

Continuous cell retention for perfusion culture and precision fermentation, lifting bioreactor output 5–10×.

100 L + · Reusable platform · Continuous
See the platform →
HV

Harvest & Downstream Debottlenecking

Reusable tubular membrane filtration — 70% lower cleaning cost and triple the effective capacity from the same footprint.

100 L + · Reusable platform · Batch or continuous
See the platform →

Biopharma and life science

Product typeTypical volumeOperationPlatformStatus
Exosomes & extracellular vesicles1 mL – 2 LTFF concentration, diafiltrationTxFlow™ GoContact us
LNP & mRNA0.5 – 500 mLDiafiltration, ethanol removalReadyPath™Contact us
Protein & nanoparticle1 mL – 2 LConcentration and desaltingTxFlow™ GoContact us
Buffer & media preparation50 mL – 2 LDirect flow: sterile, depth, virus removalDirect flowContact us
Latex & engineered particles10 mL – 2 LTFF washing and concentrationTxFlow™ GoContact us
Neoantigen & personalised vaccines1 – 50 mLDiafiltration and formulationReadyPath™Contact us
Viral vectors (AAV, LV)10 mL – 2 LClarification, concentration and buffer exchangeTxFlow™ GoContact us
Countertop perfusion0.5 – 5 LContinuous perfusion and cell retention at the benchTxFlow™ GoContact us

Every application is scoped with you before we quote. Send the feed, the volume and the target, and we will tell you where the platform stands today — including when we are not the right answer.

Water, waste and resource recovery

Cost-efficient filtration of concentrated, high-solid-content streams is essential to sustainable water management. The reusable platform provides throughput and economics that conventional cartridge systems cannot.

Product typeTypical volumeOperationPlatformStatus
Manufacturing wastewaterPlant scaleFiltration of fermentation and bioprocess waste streamsReusable platformContact us
Milk whey valorizationPlant scaleRecovery of protein and lactose from dairy streamsReusable platformContact us
Mining water pre-treatmentPlant scaleHigh-turbidity pre-filtration ahead of extractionReusable platformContact us
Fermentation medium recirculationPlant scaleCell and debris removal, COD/BOD reductionReusable platformContact us
Municipal wastewaterPlant scaleCapacity expansion ahead of UV, RO and advanced oxidationReusable platformContact us

Most of what we do is not on a list yet.

We are early, and we say so. If your molecule, feed or volume is not here, it is far more likely that we have not written it up than that the platform cannot do it. Send us the feed, the volume and the target — you will get a straight answer, including when we are not the right tool for the job.

Tell us what you are making.

Send the molecule, the volume and the operation. We will tell you which platform fits.

Contact us →